PA66 FR50 DUPONT USA
212
Form:Granules | Grade:Enhanced level
Properties:
Flame retardantGlass fiber reinforced
Typical Applications:
Fitness equipmentAutomotive sectorElectrical fieldElectronic fieldElectrical appliances
Product Description
Certificates(1)
Datasheet
Alternative(1)
Product Description
| Typical Applications: | Fitness equipment | Automotive sector | Electrical field | Electronic field | Electrical appliances |
| Properties: | Flame retardant | Glass fiber reinforced |
Certificates

Technical Data Sheet
| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| characteristic | 注塑级 | |||
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 24hr | ASTM D-570 | DAM|0.5 | % |
| 24hr | ASTM D-570 | 50%RH|- | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | ASTM D-790 | 50%RH|6900 | Mpa | |
| ASTM D-790 | DAM|8960 | Mpa | ||
| bending strength | ASTM D790/ISO 178 | 240 | kg·cm/cm(J/M)ft·lb/in | |
| Bending modulus | ASTM D790/ISO 178 | 8960 | kg·cm/cm(J/M)ft·lb/in | |
| tensile strength | ASTM D638/ISO 527 | 169 | kg/cm²(MPa)[Lb/in²] | |
| Elongation at Break | ASTM D638/ISO 527 | 2.5 | % | |
| Impact strength of cantilever beam gap | ASTM D256/ISO 179 | 100 | kg·cm/cm(J/M)ft·lb/in | |
| bending strength | ASTM D-790 | DAM|240 | Mpa | |
| ASTM D-790 | 50%RH|- | Mpa | ||
| elongation | Break | ASTM D-638 | DAM|2.5 | % |
| Break | ASTM D-638 | 50%RH|4 | % | |
| tensile strength | ASTN D-638 | DAM|169 | Mpa | |
| ASTN D-638 | 50%RH|134 | Mpa | ||
| Impact strength of cantilever beam gap | ASTM D-256 | DAM|100 | J/m | |
| ASTM D-256 | 50%RH|105 | J/m | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ASTM D-3418 | 262 | °C | |
| 262 | ℃(℉) | |||
| Hot deformation temperature | HDT | ASTM D648/ISO 75 | 257 | ℃(℉) |
| HDT | ASTM D648/ISO 75 | 235 | ℃(℉) | |
| 0.45MPa | ASTM D-648 | DAM|257 | °C | |
| 0.45MPa | ASTM D-648 | 50%RH|- | °C | |
| 1.80MPa | ASTM D-648 | DAM|235 | °C | |
| 1.80MPa | ASTM D-648 | 50%RH|- | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | ASTM D570/ISO 62 | 0.5 | % | |
| density | ASTM D792/ISO 1183 | 1.56 | ||
| Shrinkage rate | 3.2mm,flow | ASTM D-792 | DAM|0.4 | % |
| 3.2mm,flow | ASTM D-792 | 50%RH|- | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 103Hz | ASTM D-150 | 50%RH|0.113 | |
| 103Hz | ASTM D-150 | DAM|0.009 | ||
| Dielectric constant | 103Hz | ASTM D-150 | 50%RH|5.1 | |
| 103Hz | ASTM D-150 | DAM|3.6 | ||
| Volume resistivity | ASTM D-257 | 50%RH|1011 | Ω.m | |
| ASTM D-257 | DAM|1014 | Ω.m | ||
| Dielectric strength | 3.2mm | ASTM D-149 | 50%RH|15.6 | KV/mm |
| 3.2mm | ASTM D-149 | DAM|17.2 | KV/mm | |
| Volume resistivity | ASTM D257/IEC 60093 | 10 | Ω.cm | |
| Dielectric constant | ASTM D150/IEC 60250 | 3.6 | ||
| ASTM D150/IEC 60250 | 17.2 | |||
| Surface resistivity | ASTM D257/IEC 60093 | 10 | Ω | |
| Dielectric constant | 106Hz | ASTM D-150 | DAM|3.5 | |
| 106Hz | ASTM D-150 | 50%RH|3.8 | ||
| Dissipation factor | 106Hz | ASTM D-150 | DAM|0.014 | |
| 106Hz | ASTM D-150 | 50%RH|0.041 | ||
| Surface resistivity | ASTM D-257 | DAM|1014 | ||
| ASTM D-257 | 50%RH|1011 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.