Polyester, TS BMC 200 Glastic Corporation
Properties:
Filler glass fiber reinforced material
Typical Applications:
Handle electrical components electrical casing
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Handle | electrical components | electrical casing |
| Properties: | Filler | glass fiber reinforced material |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | ASTM D256 | 110to210 | J/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | V-0 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Yield | ASTM D638 | 27.6to41.4 | MPa |
| compressive strength | ASTM D695 | 124to138 | MPa | |
| bending strength | Yield | ASTM D790 | 68.9to103 | MPa |
| Bending modulus | ASTM D790 | 12400to13800 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | >260 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 23°C,24hr | ASTM D570 | 0.15to0.25 | % |
| Shrinkage rate | MD | ASTM D955 | 2.0E-4-4.0E-4 | % |
| density | ASTM D792 | 1.85to1.95 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | 1.59mm | UL 746 | PLC 1 | |
| Arc resistance | 1.59mm | ASTM D495 | >180 | sec |
| Dielectric strength | --3 | ASTM D149 | 14to15 | kV/mm |
| --2 | ASTM D149 | 15to17 | kV/mm | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Babbitt hardness | ASTM D2583 | 40to50 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.