PC/ABS C2800-701 SABIC INNOVATIVE KOREA
58
Form:Granules | Grade:Injection grade
Properties:
Flame retardantHigh mobilityHigh impact resistance
Typical Applications:
Electrical fieldElectronic fieldHousehold appliancesHousehold appliancesAutomotive sector
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical field | Electronic field | Household appliances | Household appliances | Automotive sector |
| Properties: | Flame retardant | High mobility | High impact resistance |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Bending modulus | ASTM D-790 | 2687 | Mpa | |
| bending strength | ASTM D-790 | 96 | Mpa | |
| Rockwell hardness | ASTM D-785 | 120 | R | |
| Tensile modulus | ASTM D-638 | 2687 | Mpa | |
| Impact strength of cantilever beam gap | 23℃ | ASTM D-256 | 427 | J/m |
| tensile strength | 屈伏点 | ASTM D-638 | 59 | Mpa |
| Elongation at Break | Break点 | ASTM D-638 | 50 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Long term use temperature | 含冲击 | UL -746B | 60 | °C |
| Hot deformation temperature | 1.8Mpa | ASTM D-648 | 80 | °C |
| UL flame retardant rating | UL -94 | V-0 | ||
| UL -94 | 1.5 | mm | ||
| Vicat softening temperature | ASTM D-1525 | 90 | °C | |
| Long term use temperature | 无冲击 | UL -746B | 60 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | ASTM D-570 | 0.1 | % | |
| Shrinkage rate | 3.2mm | ASTM D-955 | 4-6 | E-3 |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | ASTM D-257 | 1E+17 | ohm-cm | |
| Surface resistivity | ASTM D257 | 1E+14 | ohm-cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.