Polyester, TS Glastic® 1608 Glastic Corporation
Properties:
Filler glass fiber reinforced material
Typical Applications:
Pump parts containers engineering accessories valves valve components
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Pump parts | containers | engineering accessories | valves | valve components |
| Properties: | Filler | glass fiber reinforced material |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | Compression Molded | ASTM D256 | 520 | J/m |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Extreme Oxygen Index | ASTM D2863 | 22 | % | |
| UL flame retardant rating | 1.6mm | UL 94 | HB | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| shear strength | ASTM D732 | 77.6 | MPa | |
| Bending modulus | Compression Molded | ASTM D790 | 14500 | MPa |
| bending strength | Compression Molded | ASTM D790 | 201 | MPa |
| compressive strength | ASTM D695 | 243 | MPa | |
| Tensile modulus | Compression Molded | ASTM D638 | 14500 | MPa |
| tensile strength | Yield,Compression Molded | ASTM D638 | 38.2 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed,Compression Molded | ASTM D648 | 260 | °C |
| thermal conductivity | ASTMC177 | 0.26 | W/m/K | |
| RTI Elec | UL 746 | 54.4 | °C | |
| RTI Str | UL 746 | 54.4 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 24hr | ASTM D570 | 1.8 | % |
| density | ASTM D792 | 1.78 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric constant | 1MHz | ASTM D150 | 4.304.50 | |
| 60Hz | ASTM D150 | 5.404.90 | ||
| Dielectric strength | ASTM D149 | 18 | kV/mm | |
| Surface resistivity | ASTM D257 | 8.3E+131.5E+15 | ohms | |
| Arc resistance | ASTM D495 | 104 | sec | |
| Dissipation factor | 1MHz | ASTM D150 | 8.0E-30.12 | |
| 60Hz | ASTM D150 | 0.0265.0E-3 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.