PC LEV2200KL IDEMITSU JAPAN
135
Form:Granules
Properties:
UV resistanceHigh mobilityAging resistance
Typical Applications:
LCD application
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | LCD application |
| Properties: | UV resistance | High mobility | Aging resistance |
Certificates
No Data...
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| turbidity | 3000μm | ASTM D1003 | 0.90 | % |
| transmissivity | ISO 13468-1 | 90.0 | % | |
| Refractive index | ASTM D542 | 1.585 | ||
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.40mm | UL 94 | V-2 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ISO 178 | 90.0 | Mpa | |
| Bending modulus | ISO 178 | 2300 | Mpa | |
| Nominal tensile fracture strain | ISO 527-2 | 95 | % | |
| tensile strength | Yield | ISO 527-2 | 65.0 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI | 0.36mm | UL 746 | 130 | °C |
| RTI Imp | 0.36mm | UL 746 | 125 | °C |
| RTI Elec | 0.36mm | UL 746 | 130 | °C |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 6.5E-05 | cm/cm/°C |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 125 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Melt Volume Flow Rate (MVR) | 300°C/1.2kg | ISO 1133 | 12.0 | cm3/10min |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.23 | % |
| Shrinkage rate | MD:1.00mm | Internal Method | 0.50-0.70 | % |
| TD:1.00mm | Internal Method | 0.50-0.70 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 2 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Sale | ISO 2039-2 | 120 | |
| M-Sale | ISO 2039-2 | 50 | ||
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| ISO Shortcut | >PC< |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.