Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792A | 1.41 g/cm³ |
Shrinkage rate | | ASTM D955 | 0.20 % |
Shrinkage rate | | ISO 294-4 | 0.20 % |
Water absorption rate | | ASTMD570 | 0.80 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | Yield | ASTMD638 | 41.4 MPa |
Flexural modulus | | ASTMD790 | 8960 MPa |
bending strength | | ASTMD790 | 90.3 MPa |
compressive strength | | ASTMD695 | 153 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256A | 110 J/m |
Impact strength of cantilever beam gap | | ISO 180/2A | 6.8 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | ASTMD149 | 13 kV/mm |
arc resistance | | ASTM D495 | 125 sec |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.