PC 500R-739 SABIC EU
63
Form:Granules | Grade:Enhanced level
Properties:
enhanceGlass fiber reinforced Glass fiber reinforced b
Typical Applications:
Fiber grade
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Fiber grade |
| Properties: | enhance | Glass fiber reinforced | Glass fiber reinforced b |
Certificates

Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Water absorption rate | ASTM D-570 | 0.12 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Bending modulus | ASTM D-790 | 3445 | Mpa | |
| Impact strength of cantilever beam gap | 23°C | ASTM D-256 | 107 | J/m |
| Rockwell hardness | ASTM D-785 | 124 | ||
| tensile strength | Yield点 | ASTM D-638 | 66 | Mpa |
| Break点 | ASTM D-638 | 55 | Mpa | |
| bending strength | ASTM D-790 | 103 | Mpa | |
| elongation | Break | ASTM D-638 | 15 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | ASTM E-831 | 3.2×10 | 1/°C | |
| Vicat softening temperature | ASTM D-1525 | 154 | °C | |
| Hot deformation temperature | 0.45MPa | ASTM D-648 | 146 | °C |
| Long term use temperature | UL 746B | 130 | °C | |
| Hot deformation temperature | 1.8MPa | ASTM D-648 | 142 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Dissipation factor | 60Hz | ASTM D-150 | 0.0008 | |
| UL flame retardant rating | UL 94 | 3.0 | mm | |
| UL 94 | 5V | |||
| Shrinkage rate | 3.2mm | ASTM D-955 | 2-4 | 10 |
| density | ASTM D-792 | 1.25 | ||
| UL flame retardant rating | UL 94 | V-0 | ||
| UL 94 | 1.5 | mm | ||
| enhance | 10 | % | ||
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric constant | 60Hz | ASTM D-150 | 3.1 | |
| Dissipation factor | 1MHz | ASTM D-150 | 0.0075 | |
| Dielectric constant | 1MHz | ASTM D-150 | 3.05 | |
| Volume resistivity | ASTM D-257 | 1.0×10 | Ω.cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.