PC GN1006FM LG GUANGZHOU
132
Form:Granules | Grade:Injection grade
Properties:
Flame retardant
Typical Applications:
Electrical fieldElectronic field
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Electrical field | Electronic field |
| Properties: | Flame retardant |
Certificates

Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C,3.20mm | ASTM D256 | 720 | J/m |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 3.0mm | UL 94 | V-0 | |
| 2.5mm | UL 94 | V-0 | ||
| 2.0mm | UL 94 | V-1 | ||
| 1.5mm | UL 94 | V-2 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| elongation | Break,3.20mm | ASTM D638 | 100 | % |
| tensile strength | Yield,3.20mm | ASTM D638 | 61.8 | Mpa |
| bending strength | Yield,3.20mm | ASTM D790 | 91.2 | Mpa |
| Bending modulus | 3.20mm | ASTM D790 | 2260 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI Str | UL 746 | 120 | °C | |
| RTI Imp | UL 746 | 110 | °C | |
| RTI Elec | UL 746 | 120 | °C | |
| Vicat softening temperature | ASTM D15254 | 141 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed,6.40mm | ASTM D648 | 130 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD | ASTM D955 | 0.50-0.70 | % |
| melt mass-flow rate | 300°C/1.2kg | ASTM D1238 | 10 | g/10min |
| density | ASTM D792 | 1.20 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 3 | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ASTM D785 | 118 | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| transparency | ASTM D1003 | 87 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.