Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
MeltViscosity | | ISO 11443 | 90.0 Pa·s |
density | | ISO 1183 | 1.30 g/cm³ |
spiral flow length | | 内部方法 | 24.5 CM |
spiral flow length | | 内部方法 | 28.0 CM |
spiral flow length | | 内部方法 | 33.0 CM |
Shrinkage rate | | ISO 294-4 | 1.3 % |
Shrinkage rate | | ISO 294-4 | 1.0 % |
Water absorption rate | | ISO 62 | 0.45 % |
Water absorption rate | | ISO 62 | 0.55 % |
hardness | Test Condition | Test Method | Test Result |
---|
Shore hardness | | ISO 868 | 85 |
flammability | Test Condition | Test Method | Test Result |
---|
Burning wire flammability index | | IEC 60695-2-12 | 960 °C |
Limiting Oxygen Index | | ISO 4589-2 | 24 % |
Limiting Oxygen Index | | ISO 4589-2 | 35 % |
toxicity | | NES713 | 0.0740 |
toxicity | | NES713 | 0.150 |
toxicity | | NES713 | 0.220 |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179/1eA | 4.0 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179 | NoBreak |
Impact strength of cantilever beam gap | | ISO 180/A | 4.5 kJ/m² |
Suspended wall beam without notch impact strength | | ISO 180 | NoBreak |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | | ISO 527-2 | 105 Mpa |
Tensile strain | | ISO 527-2 | 20 % |
Flexural modulus | | ISO 178 | 3900 Mpa |
bending strength | | ISO 178 | 130 Mpa |
bending strength | | ISO 178 | 175 Mpa |
bending strength | | ISO 178 | 90.0 Mpa |
bending strength | | ISO 178 | 20.0 Mpa |
bending strength | | ISO 178 | 13.5 Mpa |
compression stress | | ISO 604 | 130 Mpa |
compression stress | | ISO 604 | 80.0 Mpa |
Tensile modulus | | ISO 527-2 | 4100 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Dissipation Factor | | IEC 60250 | 4E-03 |
Compared to the Leakage Tracking Index (CTI) | | IEC 60112 | V |
Volume resistivity | | IEC 60093 | 1E+16 ohms·cm |
Volume resistivity | | IEC 60093 | 1E+15 ohms·cm |
Volume resistivity | | IEC 60093 | 1E+09 ohms·cm |
dielectric strength | | IEC 60243-1 | 23 KV/mm |
dielectric constant | | IEC 60250 | 3.10 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/Af | 156 °C |
Heat distortion temperature | | ISO 75-2/Af | 167 °C |
Glass transition temperature (Tg) | | ISO 11357 | 143 °C |
melting temperature | | ISO 11357-3 | 343 °C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 5E-05 cm/cm/°C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 1.2E-04 cm/cm/°C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 5.5E-05 cm/cm/°C |
Linear coefficient of thermal expansion | | ISO 11359-2 | 1.4E-04 cm/cm/°C |
thermal conductivity | | ISO 22007-4 | 0.29 W/m/K |
thermal conductivity | | ISO 22007-4 | 0.32 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.