EHMWPE Quadrant EPP TIVAR® PolySteel

0

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityASTM D7921.45 g/cm³
Water absorption rateASTM D570<0.010 %
Water absorption rateSaturationASTM D570<0.010 %
hardnessTest ConditionTest MethodTest Result
Shore hardnessASTM D224064
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL 94HB
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusASTM D638703 MPa
Compression ModulusASTM D695579 MPa
compressive strengthASTM D69524.8 MPa
coefficient of frictionSteel - Static内部方法0.14
tensile strength UltimateASTM D63819.3 MPa
elongationBreakASTM D638130 %
Flexural modulusASTM D790752 MPa
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityASTM D257>1.0E+10 ohms
Thermal performanceTest ConditionTest MethodTest Result
Maximum operating temperature LongTerm, Air82 °C
Crystallization peak temperatureASTM D3418127 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.