PP H2245 TASNEE SAUDI
128
Form:Granules
Properties:
High glossMedium molecular weightHomopolymer
Typical Applications:
fibreFilamentous
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | fibre | Filamentous |
| Properties: | High gloss | Medium molecular weight | Homopolymer |
Certificates
No Data...
Technical Data Sheet
| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| purpose | 细丝.不织布 | |||
| characteristic | 挤出.高光泽.纤维 | |||
| remarks | 均聚物.中等分子量分布.高光泽 | |||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | 23℃ | ISO 180 | 28 | J/m |
| Bending modulus | 1% Secant | ISO 178 | 1500 | Mpa |
| Rockwell hardness | ISO 2039-2 | 95 | R | |
| elongation | ISO 527-2 | 8 | % | |
| tensile strength | ISO 527-2 | 34 | Mpa | |
| Bending modulus | ASTM D790/ISO 178 | 1500 | kg/cm²(MPa)[Lb/in²] | |
| Rockwell hardness | ASTM D785 | 95 | ||
| tensile strength | ASTM D638/ISO 527 | 34 | kg/cm²(MPa)[Lb/in²] | |
| Elongation at Break | ASTM D638/ISO 527 | 8 | % | |
| Impact strength of cantilever beam gap | ASTM D256/ISO 179 | 28 | kg·cm/cm(J/M)ft·lb/in | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 3146 | 163 | °C | |
| Vicat softening temperature | ISO 306/A50 | 154 | °C | |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 85 | °C |
| Vicat softening temperature | ASTM D1525/ISO R306 | 154 | ℃(℉) | |
| Melting temperature | 163 | ℃(℉) | ||
| Hot deformation temperature | HDT | ASTM D648/ISO 75 | 85 | ℃(℉) |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 230℃,2.16kg | ISO 1133 | 25 | g/10min |
| ASTM D1238/ISO 1133 | 25 | g/10min | ||
| density | ASTM D792/ISO 1183 | 0.9 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.