PEEK KT-880 NT SOLVAY USA
237
Form:Granules | Grade:Medical grade
Properties:
High mobilityAcid resistanceFatigue resistancewear resistantChemical resistancepureHigh purityProcessability
Typical Applications:
Electrical fieldElectronic fieldIndustrial componentsMedical suppliesNursing supplies
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical field | Electronic field | Industrial components | Medical supplies | Nursing supplies |
| Properties: | High mobility | Acid resistance | Fatigue resistance | wear resistant | Chemical resistance | pure | High purity | Processability |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| elongation | Break | ASTM D638 | 10-20 | % |
| Yield | ASTM D638 | 5.2 | % | |
| Impact strength of cantilever beam gap | ASTM D256 | 53 | J/m | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | -50to50℃ | ASTM E831 | 0.000050 | cm/cm/℃ |
| Chain melting temperature | ASTM D3418 | 343 | ℃ | |
| Glass transition temperature | ASTM D3418 | 147 | ℃ | |
| Hot deformation temperature | 1.82MPa,Unannealed | ASTM D648 | 160 | ℃ |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 24hr | ASTM D570 | 0.10 | % |
| Shrinkage rate | Across Flow | ASTM D955 | 1.8 | % |
| Flow | ASTM D955 | 1.7 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.