PA46 TS341 DSM HOLAND
29
Form:Granules
Properties:
Glass fiber reinforcedThermal stability
Typical Applications:
Home appliance componentsElectronic and electrical components
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Home appliance components | Electronic and electrical components |
| Properties: | Glass fiber reinforced | Thermal stability |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 无断裂 | |
| 23°C | ISO 179/1eU | 无断裂 | ||
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Flammability level | UL 94 | V-2 | ||
| UL 94 | V-2 | |||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | -- | ISO 527-2 | 3300 | Mpa |
| 120°C | ISO 527-2 | 800 | Mpa | |
| 160°C | ISO 527-2 | 650 | Mpa | |
| 180°C | ISO 527-2 | 600 | Mpa | |
| 200°C | ISO 527-2 | 500 | Mpa | |
| tensile strength | Yield | ISO 527-2 | 100 | Mpa |
| Yield, 120°C | ISO 527-2 | 50.0 | Mpa | |
| Yield, 160°C | ISO 527-2 | 40.0 | Mpa | |
| Yield, 180°C | ISO 527-2 | 35.0 | Mpa | |
| Yield, 200°C | ISO 527-2 | 30.0 | Mpa | |
| Nominal tensile fracture strain | -- | ISO 527-2 | 40 | % |
| 120°C | ISO 527-2 | > 50 | % | |
| 160°C | ISO 527-2 | > 50 | % | |
| 180°C | ISO 527-2 | > 50 | % | |
| 200°C | ISO 527-2 | > 50 | % | |
| Bending modulus | -- | ISO 178 | 3000 | Mpa |
| 120°C | ISO 178 | 800 | Mpa | |
| 160°C | ISO 178 | 600 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/B | 280 | °C |
| 1.8 MPa, Unannealed | ISO 75-2/A | 190 | °C | |
| Melting temperature | ISO 11357-3 | 295 | °C | |
| Linear coefficient of thermal expansion | Flow | ISO 11359-2 | 8.5E-5 | cm/cm/°C |
| Across Flow | ISO 11359-2 | 1.1E-4 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | 横向Flow | ISO 294-4 | 2.0 | % |
| Flow | ISO 294-4 | 2.0 | % | |
| Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 3.7 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | 1.0E+15 | ohms·cm | |
| Dielectric strength | IEC 60243-1 | 25 | KV/mm | |
| Relative permittivity | 100 Hz | IEC 60250 | 4.00 | |
| 1 MHz | IEC 60250 | 3.60 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.