Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.94 g/cm³ |
Water absorption rate | | ASTM D570 | 0.10 % |
Shrinkage rate | | ASTM D955 | 0.30 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 160to270 J/m |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
compressive strength | | ASTM D695 | 152to165 MPa |
bending strength | | ASTM D790 | 138 MPa |
tensile strength | | ASTM D638 | 34.5to41.4 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
arc resistance | | ASTM D495 | 180to240 sec |
dielectric strength | | ASTM D149 | 12 kV/mm |
dielectric constant | | ASTM D150 | 5.55 |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Continuous use temperature | | ASTM D794 | 149 °C |
Heat distortion temperature | | ASTM D648 | 204 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.