PK PK-VM GF 50 natural (4905)

0
  • Properties:
    Filler
    glass fiber reinforced material
    50%
    filler by weight
  • Usages:
    Engineering applications
    automotive applications

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
Shrinkage rateISO294-40.60 %
Shrinkage rateISO294-40.30 %
Humidity AbsorptionISO11100.40to0.50 %
densityISO11831.65 g/cm³
SpiralFlow内部方法48.0 cm
flammabilityTest ConditionTest MethodTest Result
FlameRatingUL94HB
Burning wire flammability indexIEC60695-2-12650 °C
Supplementary InformationTest ConditionTest MethodTest Result
ReinforcementContentISO117250 %
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO527-2/113500 MPa
Tensile stressBreakISO527-2/5140 MPa
Tensile strainBreakISO527-2/51.5 %
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO179/1eA15 kJ/m²
Impact strength of simply supported beam without notchISO179/1eU60 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityIEC600931E+12 ohms
Volume resistivityIEC600931E+13 ohms·cm
Thermal performanceTest ConditionTest MethodTest Result
ISO75-2/A220 °C
melting temperatureDINEN11357-1220 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.