| flammability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| UL flame retardant rating | 0.8mm | UL 94 | V-0 | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | 23°C | ISO 178 | 160 | Mpa |
| Bending modulus | 23°C | ISO 178 | 10800 | Mpa |
| Tensile strain | Break,23°C | ISO 527-2 | 1.3 | % |
| tensile strength | Yield,23°C | ISO 527-2 | 110 | Mpa |
| Tensile modulus | 23°C | ISO 527-2 | 11500 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | MD:-30to100°C | ISO 11359-2 | 4E-05 | cm/cm/°C |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 205 | °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 220 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 23°C,24hr | ISO 62 | 0.070 | % |
| Shrinkage rate | MD:3.00mm4 | Internal Method | 0.20 | % |
| TD:3.00mm2 | Internal Method | 0.80 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 0 | |
| Arc resistance | IEC 60950 | 200 | sec | |
| Dielectric strength | IEC 60243-1 | 26 | KV/mm | |
| Volume resistivity | IEC 60093 | 1.3E+17 | ohms·cm | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| BarFlowLength | 250°C,1.00mm | Internal Method | 110 | mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.