Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ISO1183 | 1.31 g/cm³ |
Water absorption rate | | | 0.45 % |
Water absorption rate | | | 0.20 % |
Water absorption rate | | ISO62 | 5.0 mg |
Water absorption rate | | ISO62 | 10.0 mg |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | | ISO2039-2 | 105 |
Ball Indentation Hardness | | ISO2039-1 | 230 MPa |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | V-0 |
UL flame retardant rating | | UL94 | V-0 |
Limiting Oxygen Index | | ISO4589-2 | 35 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
compression stress | | ISO604 | 57.0 MPa |
compression stress | | ISO604 | 29.0 MPa |
Tensile strain | | ISO527-2 | 20 % |
Tensile modulus | | ISO527-2 | 4400 MPa |
Tensile stress | | ISO527-2 | 110 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO179/1eA | 3.5 kJ/m² |
Impact strength of simply supported beam without notch | | ISO179/1eU | 无断裂 |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | IEC60093 | >1.0E+13 ohms |
Volume resistivity | | IEC60093 | >1.0E+14 ohms·cm |
dielectric strength | | IEC60243-1 | 24 kV/mm |
Relative Permittivity | | IEC60250 | 3.20 |
Relative Permittivity | | IEC60250 | 3.20 |
Dissipation Factor | | IEC60250 | 1E-03 |
Dissipation Factor | | IEC60250 | 2E-03 |
CTI | | IEC60112 | 150 V |
Thermal performance | Test Condition | Test Method | Test Result |
---|
maximum service temperature | | | 250 °C |
maximum service temperature | | | 310 °C |
Heat Deflection Temperature | | ISO75-2/A | 160 °C |
melting temperature | | | 340 °C |
Linear thermal expansion coefficient | | | 5E-05 cm/cm/°C |
Linear thermal expansion coefficient | | | 5E-05 cm/cm/°C |
Linear coefficient of thermal expansion | | | 0.25 W/m/K |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.