Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
flow | | ASTM D955 | 1.7 % |
Water absorption rate | | ASTM D570 | 0.20 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | HB |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
yield | | ASTM D638 | 62.0 MPa |
yield | | ISO 527-2 | 67.0 MPa |
fracture | | ASTM D638 | 8.0 % |
fracture | | ISO 527-2 | 5.0 % |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Charpy Notched Impact Strength | | ISO 179/1eA | 3.4 kJ/m² |
Impact strength of cantilever beam gap | | ASTM D256 | 41 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
Surface Resistivity | | ASTMD257 | 1E+16 ohms |
Volume resistivity | | ASTMD257 | 1E+14 ohms·cm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
melting temperature | | | 165 °C |
Linear coefficient of thermal expansion | | ASTM D696 | 8E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.