ABS 3001MG2A UMG JAPAN
62
Form:Granules | Grade:Electroplating grade
Properties:
Flame retardantHigh temperature resistan
Typical Applications:
Automotive components
Product Description
Certificates(1)
Datasheet
Product Description
| Typical Applications: | Automotive components |
| Properties: | Flame retardant | High temperature resistan |
Certificates

Technical Data Sheet
| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| characteristic | 电镀.涂饰 | |||
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | 24 | g/10min | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Charpy Notched Impact Strength | ASTM D256/ISO 179 | 31 | kg·cm/cm(J/M)ft·lb/in | |
| Bending modulus | ASTM D790/ISO 178 | 2.400 | kg/cm²(MPa)[Lb/in²] | |
| 2400 | Mpa | |||
| Charpy Notched Impact Strength | 31 | kJ/m² | ||
| bending strength | 23°C | ISO 178 | 65.0 | Mpa |
| Bending modulus | 23°C | ISO 178 | 2300 | Mpa |
| tensile strength | 23°C | ISO 527-2 | 41.0 | Mpa |
| Tensile modulus | 23°C | ISO 527-2 | 2200 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | HDT | ASTM D648/ISO 75 | 80 | ℃(℉) |
| HDT | 80 | °C | ||
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 8.5E-05 | cm/cm/°C |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/Af | 80.0 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| melt mass-flow rate | ASTM D1238/ISO 1133 | 24 | g/10min | |
| Shrinkage rate | MD:23°C | ISO 294-4 | 0.40-0.60 | % |
| Melt Volume Flow Rate (MVR) | 220°C/10.0kg | ISO 1133 | 24.0 | cm3/10min |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Sale,23°C | ISO 2039-2 | 107 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.