PA66 Staramide AG3 EUROSTAR FRANCE
Properties:
Filler glass fiber reinforced material 15% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material | 15% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 6.0 | kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 55 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.75mm | UL 94 | HB | |
| Burning rate | 3.00mm | FMVSS302 | 5.0 | mm/min |
| 2.00mm | FMVSS302 | 10 | mm/min | |
| UL flame retardant rating | 3.0mm | UL 94 | HB | |
| Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 650 | °C |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2/1 | 6500 | MPa | |
| bending strength | ISO 178 | 175 | MPa | |
| Bending modulus | ISO 178 | 6000 | MPa | |
| Tensile strain | Break | ISO 527-2/5 | 3.0 | % |
| tensile strength | Break | ISO 527-2/5 | 125 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI | UL 746 | 65.0 | °C | |
| RTI Imp | UL 746 | 65.0 | °C | |
| RTI Elec | UL 746 | 65.0 | °C | |
| thermal conductivity | ISO 8302 | 0.33 | W/m/K | |
| Linear coefficient of thermal expansion | TD:23to60°C | ISO 11359-2 | 1E-04 | cm/cm/°C |
| MD:23to60°C | ISO 11359-2 | 3.5E-05 | cm/cm/°C | |
| Vicat softening temperature | ISO 306/B120 | 253 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed,100mmSpan | ISO 75-2/Ae | 230 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Saturation,23°C | ISO 62 | 7.0 | % |
| Shrinkage rate | MD | Internal Method | 0.40to0.80 | % |
| density | ISO 1183 | 1.23 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | SolutionB | IEC 60112 | PLC 1 | |
| Relative permittivity | 60Hz | IEC 60250 | 3.40 | |
| Dissipation factor | 50Hz | IEC 60250 | 6.8E-03 | |
| Relative permittivity | 1MHz | IEC 60250 | 3.20 | |
| Dissipation factor | 60Hz | IEC 60250 | 6.8E-03 | |
| 1MHz | IEC 60250 | 0.015 | ||
| Compared to the anti leakage trace index | -- | IEC 60112 | PLC 1 | |
| Surface resistivity | IEC 60093 | >1.0E+16 | ohms | |
| Volume resistivity | IEC 60093 | >1.0E+16 | ohms·cm | |
| Dielectric strength | 3.20mm,in Oil | IEC 60243-1 | 19 | kV/mm |
| Relative permittivity | 50Hz | IEC 60250 | 3.40 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.