Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTMD792 | 1.60 g/cm³ |
Shrinkage rate | | ASTMD955 | 0.40到0.80 % |
Water absorption rate | | ASTMD570 | 0.050 % |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL94 | V-0 |
UL flame retardant rating | | UL94 | V-0 |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTMD256 | 10 kJ/m² |
| | ASTMD256 | 60 kJ/m² |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | Yield | ASTMD638 | 115 MPa |
Flexural modulus | | ASTMD790 | 8000 MPa |
bending strength | | ASTMD790 | 180 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric constant | | ASTMD150 | 3.20 |
Dissipation Factor | | ASTMD150 | 0.020 |
Volume resistivity | | ASTMD257 | 1.3E+16 ohms·cm |
dielectric strength | | ASTMD149 | 20 kV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
| | ASTMD648 | 215 °C |
| | ASTMD648 | 202 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.