| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 横向Flow:3.18mm | ASTM D256 | 23 | J/m |
| Flow:3.18mm | ASTM D256 | 35 | J/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 3.2mm | UL 94 | HB | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | Flow:3.18mm | ASTM D638 | 142 | MPa |
| 横向Flow:3.18mm | ASTM D638 | 103 | MPa | |
| bending strength | 3.18mm2 | ASTM D790 | 192 | MPa |
| 3.18mm3 | ASTM D790 | 150 | MPa | |
| compressive strength | 3.18mm4 | ASTM D695 | 105 | MPa |
| 3.18mm5 | ASTM D695 | 94.5 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| RTI Elec | 3.2mm | UL 746 | 130 | °C |
| RTI | 3.2mm | UL 746 | 130 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 24hr,3.18mm | ASTM D570 | 3.1 | % |
| density | ASTM D792 | 1.39 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | 3.18mm | ASTM D149 | >15 | kV/mm |
| Dielectric constant | 3.18mm,1kHz | ASTM D150 | 5.89 | |
| Dielectric strength | 3.18mm | ASTM D149 | 84600 | V |
| Dielectric constant | 3.18mm,1MHz | ASTM D150 | 4.80 | |
| Dissipation factor | 3.18mm,1kHz | ASTM D150 | 0.078 | |
| 3.18mm,1MHz | ASTM D150 | 0.045 | ||
| Arc resistance | 3.18mm | ASTM D495 | 66.2 | sec |
| Compared to the anti leakage trace index | 3.18mm | UL 746 | PLC 4 | |
| High arc combustion index | 3.18mm | UL 746 | PLC 3 | |
| High voltage arc tracing rate | 3.18mm | UL 746 | PLC 0 | mm/min |
| Hot wire ignition | 3.18mm | UL 746 | PLC 4 | sec |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.