PA6 S RV300 RADIC ITALY
55
Form:Granules | Grade:Enhanced level
Properties:
High rigidityDimensional stabilityGlass fiber reinforcedenhance
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | High rigidity | Dimensional stability | Glass fiber reinforced | enhance |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 68 | kJ/m² |
| -30°C | ISO 179/1eU | 60 | kJ/m² | |
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 11 | kJ/m² |
| -30°C | ISO 179/1eA | 9.0 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| flammability | 3.00 mm | FMVSS 302 | 0 | mm/min |
| Burning wire flammability index | 2.0 mm | IEC 60695-2-12 | 700 | °C |
| UL flame retardant rating | 0.8 mm | UL 94 | HB | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ISO 178 | 245 | Mpa | |
| Bending modulus | ISO 178 | 8550 | Mpa | |
| Tensile strain | Break | ISO 527-2/1A/5 | 3.1 | % |
| tensile strength | Break | ISO 527-2/1A/5 | 175 | Mpa |
| Tensile modulus | ISO 527-2/1A/1 | 9600 | Mpa | |
| injection | Test Condition | Test Method | Test Result | Test Unit |
| Drying temperature - hot air dryer | 80 | °C | ||
| Drying time - hot air dryer | 2.0 to 4.0 | hr | ||
| Dew Point - Hot Air Drying Machine | -20 | °C | ||
| Suggested maximum moisture content | 0.15 | % | ||
| Processing (melt) temperature | 240 to 280 | °C | ||
| Mold temperature | 80 to 90 | °C | ||
| Injection speed | 中等偏快 | |||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8 MPa, Unannealed | ISO 75-2/Af | 200 | °C |
| 0.45 MPa, Unannealed | ISO 75-2/Bf | 215 | °C | |
| Melting temperature | ISO 11357-3 | 220 | °C | |
| Vicat softening temperature | ISO 306/B50 | 210 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium, 23°C, 2.00 mm, 50% RH | ISO 62 | 2.0 | % |
| Saturation, 23°C, 2.00 mm | ISO 62 | 7.5 | % | |
| Shrinkage rate | Flow | ISO 294-4 | 0.30 | % |
| 横向Flow | ISO 294-4 | 0.80 | % | |
| density | ISO 1183 | 1.35 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | Solution A | IEC 60112 | PLC 1 | |
| Volume resistivity | IEC 60093 | 1.0E+15 | ohms·cm | |
| Surface resistivity | IEC 60093 | 1.0E+12 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.