PA66 HTNFR52G35 BK337 DUPONT JAPAN
165
Form:Granules | Grade:Injection grade
Properties:
Low temperature resistancHigh rigidityFlame retardantHigh temperature resistan
Typical Applications:
Wire and cable
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Wire and cable |
| Properties: | Low temperature resistanc | High rigidity | Flame retardant | High temperature resistan |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 38 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.75mm | IEC 60695-11-10,-20 | HB | |
| 1.5mm | UL 94 | HB | ||
| 0.75mm | UL 94 | HB | ||
| Burning rate | 1.00mm | ISO 3795 | <100 | mm/min |
| FMVSS flammability | FMVSS302 | B | ||
| Extreme Oxygen Index | ISO 4589-2 | 25 | % | |
| UL flame retardant rating | 1.5mm | IEC 60695-11-10,-20 | HB | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Break | ISO 527-2 | 1.8 | % |
| tensile strength | Break | ISO 527-2 | 180 | Mpa |
| Tensile modulus | ISO 527-2 | 11700 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 285 | °C |
| Linear coefficient of thermal expansion | TD | ISO 11359-2 | 6E-05 | cm/cm/°C |
| MD | ISO 11359-2 | 2E-05 | cm/cm/°C | |
| Melting temperature | ISO 11357-3 | 310 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD | ISO 294-4 | 0.20 | % |
| TD | ISO 294-4 | 0.80 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | 1E+15 | ohms·cm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.