PVC S&E Wire & Cable GA-2190E-FR CLEAR S&E Polymer Solutions, Inc.
0
- Usages:Wire and cable applications
Technical Data Sheet
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Extreme Oxygen Index | ASTM D2863 | 27 % | |
| ASTM D2863 | 27 % |
| elastomer | Test Condition | Test Method | Test Result |
|---|---|---|---|
| tensile strength | 100%Strain | ASTM D412 | 9.31 MPa |
| Yield | ASTM D412 | 16.2 MPa | |
| elongation | Break | ASTM D412 | 310 % |
| tensile strength | 100%Strain | ASTM D412 | 9.31 MPa |
| Yield | ASTM D412 | 16.2 MPa | |
| elongation | Break | ASTM D412 | 310 % |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Brittle temperature | ASTM D746 | -30.0 °C | |
| ASTM D746 | -30.0 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| density | ASTM D792 | 1.20to1.26 g/cm³ | |
| ASTM D792 | 1.20to1.26 g/cm³ |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shore hardness | ShoreA,3Sec | ASTM D2240 | 87to93 |
| ShoreA | ASTM D2240 | 95 | |
| ShoreA | ASTM D2240 | 95 | |
| ShoreA,3Sec | ASTM D2240 | 87to93 |
| aging | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Volume change | 100°C,168hr | 2.2 % | |
| 100°C,168hr | 2.2 % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.