Technical Data Sheet
optical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
gloss | ASTM D2457 | 139 |
Supplementary Information | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ASTM D1204 | 1.6 % | |
ASTM D1204 | 0.0 % | ||
WettingTension-Nonplatedsurface | ASTM D2578 | 44 dyne/cm |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
ASTM D1894 | 0.48 |
film | Test Condition | Test Method | Test Result |
---|---|---|---|
film thickness | ASTM D374 | 12 µm | |
tensile strength | ASTM D882 | 235 MPa | |
ASTM D882 | 241 MPa | ||
elongation | ASTM D882 | 130 % | |
ASTM D882 | 110 % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.