physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D792 | 1.84 g/cm³ |
Water absorption rate | | ASTM D570 | 0.40 % |
hardness | Test Condition | Test Method | Test Result |
---|
Rockwell hardness | M-Scale | ASTM D785 | 94 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | HB |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
bending strength | Yield | ASTM D790 | 124 MPa |
Compression Modulus | | ASTM D695 | 12400 MPa |
compressive strength | | ASTM D695 | 310 MPa |
compressive strength | | ASTM D695 | 68.9 MPa |
compressive strength | | ASTM D695 | 79.3 MPa |
compressive strength | | ASTM D695 | 110 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 430 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | ASTM D149 | 2.0 kV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
thermal conductivity | | ASTMC177 | 0.69 W/m/K |
Linear coefficient of thermal expansion | | ASTM D696 | 1.1E-05 cm/cm/°C |
Linear coefficient of thermal expansion | | ASTM D696 | 7E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.