PA6 Starflam PX05003 EUROSTAR FRANCE
Properties:
Filler glass fiber reinforced material
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 4.0 | kJ/m² |
| Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 30 | kJ/m² |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | V-2 | |
| Burning wire flammability index | 0.8mm | IEC 60695-2-12 | 960 | °C |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | ISO 527-2/1 | 6200 | MPa | |
| tensile strength | Yield | ISO 527-2/5 | 91.0 | MPa |
| Tensile strain | Break | ISO 527-2/5 | 2.4 | % |
| Bending modulus | ISO 178 | 5700 | MPa | |
| bending strength | ISO 178 | 140 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed,64.0mmSpan | ISO 75-2/Af | 190 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | MD:4.00mm | Internal Method | 0.40 | % |
| density | ISO 1183 | 1.34 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Compared to the anti leakage trace index | IEC 60112 | PLC 1 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.