Polyester, TP Mar-Bal MB2000-20 Mar-Bal, Inc.
0
- Properties:Filler glass fiber reinforced material 20% filler by weight
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of cantilever beam gap | ASTM D256 | 430to530 J/m |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| UL flame retardant rating | UL 94 | V-0 |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| shear strength | ASTM D732 | 62.1to75.8 MPa | |
| compressive strength | ASTM D695 | 138to165 MPa | |
| Compressive modulus | ASTM D695 | 393000to421000 MPa | |
| bending strength | ASTM D790 | 131to152 MPa | |
| Bending modulus | ASTM D790 | 11700to13800 MPa | |
| tensile strength | ASTM D638 | 34.5to55.2 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Hot deformation temperature | 1.8MPa,Unannealed | ASTM D648 | >260 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Water absorption rate | 24hr | ASTM D570 | 0.12 % |
| Shrinkage rate | MD | ASTM D955 | 0.050to0.20 % |
| ASTM D1895 | 2.0 | ||
| density | ASTM D792 | 1.75to1.80 g/cm³ |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Inclined plate electric trace | ASTM D2303 | >1000 min | |
| Arc resistance | ASTM D495 | >185 sec | |
| Dielectric strength | ASTM D149 | >14 kV/mm |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Babbitt hardness | ASTM D2583 | 35to45 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.