Share
Add to compare

PA66 A218V25 BK SOLVAY FRANCE

26

Form:Granules | Grade:Enhanced level

Properties:
Filler: Glass fiber reinf25% filler by weight
Product Description
Certificates(0)
Datasheet

Product Description

Properties:Filler: Glass fiber reinf | 25% filler by weight

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch23°CISO 179/1eU58kJ/m²
Suspended wall beam without notch impact strength23°CISO 180/1U55kJ/m²
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant rating0.8mmUL 94HB
UL flame retardant rating1.6mmUL 94HB
UL flame retardant rating3.2mmUL 94HB
Burning wire flammability index1.6mmIEC 60695-2-12650°C
Extreme Oxygen IndexISO 4589-223%
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
bending strength23°CASTM D790250Mpa
bending strength23°CISO 178240Mpa
Tensile modulus23°CISO 527-2/1A8400Mpa
tensile strengthYield,23°CASTM D638160Mpa
tensile strengthBreak,23°CISO 527-2/1A165Mpa
elongationBreak,23°CASTM D6383.3%
Tensile strainBreak,23°CISO 527-23.0%
Bending modulus23°CASTM D7907300Mpa
Bending modulus23°CISO 1787300Mpa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.8MPa,UnannealedASTM D648245°C
Hot deformation temperature1.8MPa,UnannealedISO 75-2/Af250°C
Melting temperatureISO 11357-3262°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Water absorption rate23°C,24hrISO 620.90%
Water absorption rateSaturation,23°CISO 626.2%
Water absorption rateEquilibrium,23°C,50%RHISO 622.3%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Surface resistivityIEC 600936E+15ohms
Volume resistivityIEC 600931E+15ohms·cm
Dielectric strength2.00mmIEC 60243-132KV/mm
Relative permittivityIEC 602503.70
Dissipation factorIEC 602500.010
Compared to the anti leakage trace indexSolutionAIEC 60112PLC 0
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.