EAA 3330 STYRON US
215
Form:Granules | Grade:Extrusion grade
Properties:
Heat sealing performanceHigh toughness
Typical Applications:
Food service sector
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Food service sector |
| Properties: | Heat sealing performance | High toughness |
Certificates
No Data...
Technical Data Sheet
| Other performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Starting temperature of heat sealing | Internal Method | 92.8 | ℃ | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Elongation at Break | Compression Molded | ISO 527-2 | 520 | % |
| Compression Molded | ASTM D-638 | 520 | % | |
| tensile strength | Compression Molded,Break | ISO 527-2 | 17.4 | MPa |
| elongation | Break,Compression Molded | ASTMD638 | 520 | % |
| tensile strength | Break,Compression Molded | ASTMD638 | 17.4 | Mpa |
| Yield,Compression Molded | ASTMD638 | 8.34 | Mpa | |
| Compression Molded,Break | ASTM D-638 | 17.4 | MPa | |
| Yield,Compression Molded | ISO 527-2 | 8.34 | MPa | |
| Yield,Compression Molded | ASTM D-638 | 8.34 | MPa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Vicat softening temperature | ISO 306 | 85 | ℃ | |
| ASTM D-1525 | 85 | ℃ | ||
| Melting temperature | Internal Method | 100 | °C | |
| Vicat softening temperature | ASTMD1525 | 85.0 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Content of comonomer | Internal Method | 6.5 | % | |
| melt mass-flow rate | 190°C/2.16kg | ASTMD1238 | 5.8 | g/10min |
| film | Test Condition | Test Method | Test Result | Test Unit |
| Water vapor permeability | 38°C,90%RH | DIN 53122/2 | 0.40 | g·mm/m²/atm/24hr |
| Initial sealing temperature | Internal Method | 92.8 | °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.