Share
Add to compare

PVC, Rigid Hoffman PVC V7-54 Hoffman Plastic Compounds Inc.

Product Description
Certificates(0)
Datasheet

Product Description

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Impact strength of cantilever beam gap3.17mmASTM D256530J/m
flammabilityTest ConditionTest MethodTest ResultTest Unit
UL flame retardant ratingUL 94V-0
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Tensile modulusASTM D6382620MPa
tensile strengthASTM D63845.5MPa
Bending modulusASTM D7902760MPa
bending strengthASTM D79075.8MPa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.8MPa,AnnealedASTM D64868.9°C
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityASTM D7921.39g/cm³
Shrinkage rateMDASTM D9550.30to0.50%
hardnessTest ConditionTest MethodTest ResultTest Unit
Shore hardnessShoreDASTM D224080
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.