PA12 LV-5H EMS-CHEMIE USA
38
Form:Granules | Grade:Injection grade
Properties:
Low temperature impact regas barrier
Typical Applications:
Electrical applicationschipShell
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electrical applications | chip | Shell |
| Properties: | Low temperature impact re | gas barrier |
Certificates
No Data...
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Charpy Notched Impact Strength | -30℃-30°C | ISO 179/1eA | 15 | kJ/m² |
| 23℃23°C | ISO 179/1eA | 19 | kJ/m² | |
| Impact strength of simply supported beam without notch | -30℃-30°C | ISO 179/1eU | 90 | kJ/m² |
| 23℃23°C | ISO 179/1eU | 90 | kJ/m² | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shore hardness | Shore D,15 SecShore D,15 Sec | ISO 868 | -- | |
| Ball Pressure Test | ISO 2039-1 | -- | Mpa | |
| Tensile modulus | ISO 527-2 | 12000 | Mpa | |
| tensile strength | BreakBreak | ISO 527-2 | 155 | Mpa |
| Tensile stress | BreakBreak | ISO 527-2 | 5 | % |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Continuous use temperature | ---- 33 | ISO 2578 | 90.0 to 120 | °C |
| ---- 44 | Internal Method | 150 | °C | |
| Melting temperature | ISO 11357-3 | 178 | °C | |
| Linear coefficient of thermal expansion | MDFlow | ISO 11359-2 | 0.000015 | 1/℃ |
| TDTransverse | ISO 11359-2 | 0.00012 | 1/℃ | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ISO 1183 | 1.47 | g/cm³ | |
| Shrinkage rate | TDAcross Flow | ISO 294-4 | 0.5 | % |
| MDFlow | ISO 294-4 | 0.1 | % | |
| Water absorption rate | Saturation,23℃Saturation, 73°F | ISO 62 | 0.8 | % |
| Equilibrium,23℃,50% RHEquilibrium, 73°F, 50% RH | ISO 62 | 0.4 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | -- | ohms | |
| Volume resistivity | IEC 60093 | -- | ohms·cm | |
| Dielectric strength | IEC 60243-1 | -- | KV/mm | |
| Compared to the anti leakage trace index | IEC 60112 | V | ||
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| Flammability level | UL 94 | HB |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.