Share
Add to compare

PA12 LV-5H EMS-CHEMIE USA

38

Form:Granules | Grade:Injection grade

Properties:
Low temperature impact regas barrier
Typical Applications:
Electrical applicationschipShell
Product Description
Certificates(0)
Datasheet

Product Description

Typical Applications:Electrical applications | chip | Shell
Properties:Low temperature impact re | gas barrier

Certificates

No Data...

Technical Data Sheet

impact performanceTest ConditionTest MethodTest ResultTest Unit
Charpy Notched Impact Strength-30℃-30°CISO 179/1eA15kJ/m²
Charpy Notched Impact Strength23℃23°CISO 179/1eA19kJ/m²
Impact strength of simply supported beam without notch-30℃-30°CISO 179/1eU90kJ/m²
Impact strength of simply supported beam without notch23℃23°CISO 179/1eU90kJ/m²
mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Shore hardnessShore D,15 SecShore D,15 SecISO 868--
Ball Pressure TestISO 2039-1--Mpa
Tensile modulusISO 527-212000Mpa
tensile strengthBreakBreakISO 527-2155Mpa
Tensile stressBreakBreakISO 527-25%
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Continuous use temperature---- 33ISO 257890.0 to 120°C
Continuous use temperature---- 44Internal Method150°C
Melting temperatureISO 11357-3178°C
Linear coefficient of thermal expansionMDFlowISO 11359-20.0000151/℃
Linear coefficient of thermal expansionTDTransverseISO 11359-20.000121/℃
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
densityISO 11831.47g/cm³
Shrinkage rateTDAcross FlowISO 294-40.5%
Shrinkage rateMDFlowISO 294-40.1%
Water absorption rateSaturation,23℃Saturation, 73°FISO 620.8%
Water absorption rateEquilibrium,23℃,50% RHEquilibrium, 73°F, 50% RHISO 620.4%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Surface resistivityIEC 60093--ohms
Volume resistivityIEC 60093--ohms·cm
Dielectric strengthIEC 60243-1--KV/mm
Compared to the anti leakage trace indexIEC 60112V
flame retardant performanceTest ConditionTest MethodTest ResultTest Unit
Flammability levelUL 94HB
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.