PA6 Nylux 6/G33FL BLK KMI Group, Inc.
Properties:
Filler glass fiber reinforced material 33% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material | 33% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 5 | kJ/m² |
| Bending modulus | 23°C | ISO 178 | 5800 | MPa |
| Tensile modulus | 23°C | ISO 527-2 | 8500 | MPa |
| Elongation at Break | 23°C | ISO 527-2 | 3 | % |
| tensile strength | 23°C | ISO 527-2 | 140 | MPa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | Melting Temperature | ISO 3146 | 220 | °C |
| Vicat softening temperature | ISO 306/A50 | 210 | °C | |
| Hot deformation temperature | 1.80MPaAnnealed | ISO 75-2/Af | 205 | °C |
| 0.45MPaUnannealed | ISO 75-2/Bf | 215 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 收缩率 | ISO 2577 | 0.25-0.55 | % |
| (23°C,24hr) | ISO 62 | 6.0 | % | |
| density | ISO 1183 | 1.36 | g/cm³ | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | IEC 60093 | 1E+13 | Ω.cm | |
| Volume resistivity | IEC 60093 | 1E+15 | Ω.cm | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | ISO 2039-2 | 122 | R | |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL -94 | HB | 0.8mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.