ABS XANTAR® C CP 200 Mitsubishi Chemical Corporation
0
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 无断裂 |
| Impact strength of cantilever beam gap | 23°C | ISO 180/4A | 50 kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 无断裂 |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| bending strength | ISO 178 | 67.0 MPa | |
| Nominal tensile fracture strain | ISO 527-2 | >50 % | |
| Tensile strain | Yield | ISO 527-2 | 4.5 % |
| tensile strength | Yield | ISO 527-2 | 45.0 MPa |
| Tensile modulus | ISO 527-2 | 2000 MPa | |
| Bending modulus | ISO 178 | 1800 MPa |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Linear coefficient of thermal expansion | TD | ISO 11359-2 | 9E-05 cm/cm/°C |
| MD | ISO 11359-2 | 9E-05 cm/cm/°C | |
| Vicat softening temperature | ISO 306/B50 | 112 °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 95.0 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| density | ISO 1183 | 1.10 g/cm³ | |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.70 % |
| Shrinkage rate | MD | ISO 294-4 | 0.60 % |
| melt mass-flow rate | 260°C/5.0kg | ISO 1133 | 26 g/10min |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Volume resistivity | IEC 60093 | >1.0E+15 ohms·cm | |
| Surface resistivity | IEC 60093 | >1.0E+15 ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.