PA66 AKROMID®  A3 1 FR

32
  • Properties:
    Glass fiber reinforced
    Flame retardant
    Halogen-free
  • Usages:
    switch
    Shell
    Electronic field
    Electrical field

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
Shrinkage rateISO294-41.1 %
Shrinkage rateISO294-41.1 %
flammabilityTest ConditionTest MethodTest Result
UL flame retardant ratingUL94V-0
UL flame retardant ratingUL94V-0
UL flame retardant ratingUL94V-0
Burning wire flammability indexIEC60695-2-12960 °C
Burning wire flammability indexIEC60695-2-12960 °C
Hot filament ignition temperatureIEC60695-2-13775 °C
Hot filament ignition temperatureIEC60695-2-13775 °C
Hot filament ignition temperatureIEC60695-2-13775 °C
Limiting Oxygen IndexISO4589-232 %
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO527-2/13500 Mpa
Tensile stressISO527-2/5080.0 Mpa
Tensile strainISO527-2/50>5.0 %
Bending modulus 2ISO1783300 Mpa
Bending stress 2ISO178125 Mpa
Fracture bending strain 3ISO1786.2 %
Impact resistanceTest ConditionTest MethodTest Result
Impact strength of simply supported beam without notchISO179/1eU80 kJ/m²
Impact strength of simply supported beam without notchISO179/1eU85 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Surface ResistivityIEC600931E+13 ohms
Volume resistivityIEC600931E+13 ohms·cm
dielectric strengthIEC60243-119 KV/mm
CTIIEC60112600 V
Thermal performanceTest ConditionTest MethodTest Result
ISO75-2/B220 °C
ISO75-2/A80.0 °C
Melting temperature 5DINEN11357-1260 °C
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.