TP, Unspecified R-4242 HAPCO USA
0
- Usages:Switches battery boxes electrical and electronic applications cable shields
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Suspended wall beam without notch impact strength | ASTM D256 | 29 J/m | |
| Impact strength of cantilever beam gap | ASTM D256 | 22 J/m |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile modulus | ASTM D638 | 1810 MPa | |
| elongation | Break | ASTM D638 | 3.4 % |
| tensile strength | ASTM D638 | 34.5 MPa | |
| bending strength | ASTM D790 | 2.05 MPa |
| thermosetting | Test Condition | Test Method | Test Result |
|---|---|---|---|
| GelTime | 25°C | ASTM D2971 | 8.0to10.0 min |
| stripping time | 21°C | 60to240 min | |
| Thermosetting mixed viscosity | 25°C | ASTM D4878 | 2500 cP |
| Thermosetting components | PartB | 按重量计算的混合比:100.按容量计算的混合比:100 | |
| PartA | 按重量计算的混合比:100.按容量计算的混合比:100 |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Usage temperature | 100 °C | ||
| thermal conductivity | 0.37 W/m/K |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| density | ASTM D4669 | 1.50to1.70 g/cm³ | |
| Shrinkage rate | MD | ASTM D2566 | 0.15to0.30 % |
| Weight Percubicinch | 25 g |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Dielectric constant | 100kHz | ASTM D150 | 3.30 |
| Dissipation factor | 25°C,100kHz | ASTM D150 | 0.019 |
| Dielectric constant | 1kHz | ASTM D150 | 4.00 |
| Dielectric strength | ASTM D149 | 20 kV/mm | |
| Volume resistivity | ASTM D257 | 2E+15 ohms·cm |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shore hardness | ShoreD | ASTM D2240 | 80 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.