Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D1505 | 1.53 g/cm³ |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | V-0 |
film | Test Condition | Test Method | Test Result |
---|
tensile strength | Break | ASTM D882 | 193 MPa |
elongation | Break | ASTM D882 | 90 % |
Elmendorf tear strength | | ASTM D1922 | 36 g |
film thickness | | | 76 µm |
Secant modulus | | ASTM D882 | 2790 MPa |
Electrical performance | Test Condition | Test Method | Test Result |
---|
arc resistance | | ASTM D495 | 90.0 sec |
Compared to the Leakage Tracking Index (CTI) | | UL 746 | PLC 3 |
High arc combustion index (HAI) | | UL 746 | PLC 3 |
High Voltage Arc Traceability Rate (HVTR) | | UL 746 | PLC 4 mm/min |
Hot wire ignition (HWI) | | UL 746 | PLC 0 sec |
Thermal performance | Test Condition | Test Method | Test Result |
---|
RTI | | UL 746 | 210 °C |
RTI Elec | | UL 746 | 240 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.