PA66 Vydyne® M344
95
- Properties:TougheningLubricityFlame retardant
- Usages:Industrial applicationsElectronic fieldElectrical field
- Certificates:UL
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ISO294-4 | 1.8 % | |
ISO294-4 | 1.3 % | ||
Water absorption rate | ISO62 | 0.80 % | |
ISO62 | 1.9 % |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL94 | V-0 | |
UL94 | V-0 | ||
UL94 | V-0 | ||
UL94 | V-0 | ||
UL94 | V-0 | ||
Burning wire flammability index | IEC60695-2-12 | 960 °C | |
IEC60695-2-12 | 960 °C | ||
IEC60695-2-12 | 960 °C | ||
Hot filament ignition temperature | IEC60695-2-13 | 700 °C | |
IEC60695-2-13 | 700 °C | ||
IEC60695-2-13 | 725 °C | ||
Limiting Oxygen Index | ISO4589-2 | 30 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO527-2 | 3500 Mpa | |
Tensile stress | ISO527-2 | 60.0 Mpa | |
Tensile strain | ISO527-2 | 5.2 % | |
ISO527-2 | 35 % | ||
Flexural modulus | ISO178 | 3000 Mpa | |
bending strength | ISO178 | 90.0 Mpa | |
Poisson's ratio | ISO527-2 | 0.40 |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO179/1eU | NoBreak | |
ISO179/1eU | NoBreak |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
dielectric strength | IEC60243 | 26 KV/mm | |
arc resistance | ASTMD495 | PLC6 | |
CTI | IEC60112 | 400to599 V | |
High arc combustion index (HAI) | UL746 | PLC 0 | |
UL746 | PLC 0 | ||
VolumeResistivity | IEC60093 | 1E+10 ohms·cm | |
High arc combustion index (HAI) | UL746 | PLC 0 | |
High Voltage Arc Traceability Rate (HVTR) | UL746 | PLC 1 | |
Hot wire ignition (HWI) | UL746 | PLC 0 | |
UL746 | PLC 0 | ||
UL746 | PLC 0 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
RTI Elec | UL746 | 130 °C | |
RTI Imp | UL746 | 65.0 °C | |
UL746 | 65.0 °C | ||
UL746 | 95.0 °C | ||
UL746 | 95.0 °C | ||
RTI Str | UL746 | 65.0 °C | |
UL746 | 95.0 °C | ||
UL746 | 95.0 °C | ||
UL746 | 95.0 °C | ||
Heat distortion temperature | ISO75-2/B | 186 °C | |
ISO75-2/A | 65.0 °C | ||
ISO3146 | 250 °C | ||
ISO11359-2 | 1E-04 cm/cm/°C | ||
ISO11359-2 | 1E-04 cm/cm/°C | ||
RTI Elec | UL746 | 65.0 °C | |
UL746 | 130 °C | ||
UL746 | 130 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.