PBT TV4 270 DSM Additive Manufacturing
Properties:
Filler glass fiber reinforced material 35% filler by weight
Product Description
Certificates(0)
Datasheet
Product Description
| Properties: | Filler | glass fiber reinforced material | 35% | filler by weight |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 65 | kJ/m² |
| -30°C | ISO 180/1A | 65 | kJ/m² | |
| tensile strength | 23°C | ISO 527-2 | 145 | MPa |
| Elongation at Break | 23°C | ISO 527-2 | 2.50 | % |
| Tensile modulus | 23°C | ISO 527-2 | 11500 | MPa |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 13 | kJ/m² |
| -30°C | ISO 179/1eU | 13 | kJ/m² | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 0.45MPaUnannealed | ISO 75-2/Bf | 220 | °C |
| 1.80MPaAnnealed | ISO 75-2/Af | 210 | °C | |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 3.5E-05 | cm/cm/°C |
| TD | ISO 11359-2 | 7E-05 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | (Equilibrium,23°C,50%RH) | ISO 62 | 0.15 | % |
| density | ISO 1183 | 1.57 | g/cm³ | |
| Shrinkage rate | MD | ISO 294-4 | 0.30 | % |
| TD | ISO 294-4 | 1.10 | % | |
| Water absorption rate | (Saturation,23°C) | ISO 62 | 0.25 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | IEC 60093 | 1E+12 | Ω.cm | |
| Dielectric strength | IEC 60243-1 | 42 | KV/mm | |
| Dissipation factor | 相对漏电起痕指数 | IEC 60112 | 475 | V |
| flame retardant performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL -94 | HB | 1.50mm | |
| UL -94 | HB | 3.00mm | ||
| UL -94 | 0.75mm |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.