Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
melt mass-flow rate | | ISO 1133 | 31 g/10min |
melt mass-flow rate | | ISO 294-4 | 0.4-0.7 % |
hardness | Test Condition | Test Method | Test Result |
---|
ball-indentation hardness | | ISO 2039-1 | 110 Mpa |
Other performance | Test Condition | Test Method | Test Result |
---|
melting temperature | | ISO 294 | 240 °C |
injection speed | | ISO 294 | 240 mm/sec |
burning rate | | ISO 3795 | 60 mm/min |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | | ISO 527-2 | 46 Mpa |
elongation at break | | ISO 527-2 | 2.6 % |
elongation at break | | ISO 527-2 | >=15 % |
Tensile modulus | | ISO 527-2 | 2400 Mpa |
bending strength | | ISO 178 | 70 Mpa |
Flexural modulus | | ISO 178 | 2400 Mpa |
Charpy Notched Impact Strength | | ISO 179/1eA | 15 kJ/m² |
Charpy Notched Impact Strength | | ISO 179/1eA | 7 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eU | 110 kJ/m² |
Impact strength of simply supported beam without notch | | ISO 179/1eU | 90 kJ/m² |
Impact strength of cantilever beam gap | | ISO 180/1A | 15 kJ/m² |
Impact strength of cantilever beam gap | | ISO 180/1A | 7 kJ/m² |
Flame retardant performance | Test Condition | Test Method | Test Result |
---|
GWIT | | IEC 60695-2-12 | 700 °C |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric constant | | IEC 60250 | 2.9 1MHz |
dielectric constant | | IEC 60250 | 3 100HZ |
Dissipation Factor | | IEC 60250 | 0.05 |
Dissipation Factor | | IEC 60250 | 0.09 |
Dissipation Factor | | IEC 60112 | 600 V |
Volume resistivity | | IEC 60093 | 1E+13 Ω.cm |
Surface Resistivity | | IEC 60093 | 1E+15 Ω.cm |
dielectric strength | | IEC 60243-1 | 35 KV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Heat distortion temperature | | ISO 75-2/Bf | 98 °C |
Heat distortion temperature | | ISO 75-2/Af | 94 °C |
vicat | | ISO 306/A50 | 99 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.