PA/MXD6 RENY™ 1022F BK MITSUBISHI ENGINEERING JAPAN
129
- Properties:Glass fiber reinforced
- Usages:Electronic and Electrical Applications
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Filling amount | 50 % | ||
Water absorption rate | ASTM D570 | 0.14 % | |
Shrinkage rate | ASTM D955 | 0.40 % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Flexural modulus | ASTM D790 | 17.4 GPa | |
compressive strength | ASTM D695 | 256 Mpa | |
Rockwell hardness | ASTM D785 | 111 M | |
tensile strength | ASTM D638 | 285 Mpa | |
bending strength | ASTM D790 | 380 Mpa |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
dielectric strength | ASTM D149 | 32.2 MV/m | |
dielectric constant | ASTM D150 | 38 Pf/m | |
Dielectric loss | ASTM D495 | 129 S |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTM D648 | 234 °C | |
UL flame retardant rating | UL 94 | HB |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.