| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 80 | kJ/m² |
| -30°C | ISO 180/1U | 70 | kJ/m² | |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 90 | kJ/m² |
| -30°C | ISO 179/1eU | 75 | kJ/m² | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | FlexuralStrainatFlexuralStrength5(23°C) | 4.3 | % | |
| 23°C | ISO 178 | 250 | Mpa | |
| 3.5%Strain | ISO 178/A | 240 | Mpa | |
| Bending modulus | 23°C | ISO 178/A | 8600 | Mpa |
| Tensile strain | Break,23°C | ISO 527-2/5 | 3.4 | % |
| tensile strength | Break,23°C | ISO 527-2/5 | 160 | Mpa |
| Tensile modulus | 23°C | ISO 527-2/1 | 9300 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Melting temperature | ISO 11357-3 | 221 | °C | |
| Vicat softening temperature | ISO 306/B120 | 212 | °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 202 | °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 218 | °C | |
| Linear coefficient of thermal expansion | MD:23to55°C | ISO 11359-2 | 2E-05 | cm/cm/°C |
| TD:23to55°C | ISO 11359-2 | 1E-04 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 2.0 | % |
| Saturation,23°C | ISO 62 | 6.6 | % | |
| Shrinkage rate | MD:120°C,2hr,2.00mm3 | ISO 294-4 | 0.10 | % |
| MD:280°C,2.00mm2 | ISO 294-4 | 0.30 | % | |
| TD:120°C,2hr,2.00mm3 | ISO 294-4 | 0.10 | % | |
| TD:280°C,2.00mm2 | ISO 294-4 | 0.80 | % | |
| film | Test Condition | Test Method | Test Result | Test Unit |
| Thin film puncture strength | --7 | ISO 6603-2 | 990 | N |
| --6 | ISO 6603-2 | 765 | N | |
| --7 | ISO 6603-2 | 4.30 | J | |
| --6 | ISO 6603-2 | 2.50 | J | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| ISO Shortcut | ISO 1874 | PA6-HI.GHR.14-090.GF30 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.