Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
Water absorption rate | | ASTM D570 | 0.0to0.20 % |
optical performance | Test Condition | Test Method | Test Result |
---|
optical density | | ASTME662 | 8.00 |
flammability | Test Condition | Test Method | Test Result |
---|
FlameSpread-RadiantPanelIndex | | ASTME162 | 19.5 |
smoke toxicity | | | 25 ppm |
smoke toxicity | | | 600 ppm |
smoke toxicity | | | 12250 ppm |
smoke toxicity | | | 3 ppm |
smoke toxicity | | | 0 ppm |
smoke toxicity | | | 0 ppm |
smoke toxicity | | | 0 ppm |
smoke toxicity | | | 1 ppm |
smoke toxicity | | | 0 ppm |
smoke toxicity | | | 3 ppm |
UL flame retardant rating | | UL 94 | V-0 |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
Tensile modulus | | ASTM D638 | 9650 MPa |
tensile strength | | ASTM D638 | 159 MPa |
Flexural modulus | | ASTM D790 | 12400 MPa |
bending strength | | ASTM D790 | 193 MPa |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 1300 J/m |
Electrical performance | Test Condition | Test Method | Test Result |
---|
dielectric strength | | ASTM D149 | 15 kV/mm |
arc resistance | | ASTM D495 | 180 sec |
Inclined plate electric trace | | ASTM D2303 | >600 min |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Linear coefficient of thermal expansion | | ASTM D696 | 2.2E-05 cm/cm/°C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.