PCT SCHULADUR® HT GF 30

0
  • Properties:
    Filler
    glass fiber reinforced material
    30%
    filler by weight

Technical Data Sheet

physical property Test ConditionTest MethodTest Result
densityISO1183/A1.44 g/cm³
Melt volume flow rateISO113320.0 cm³/10min
Mechanical propertiesTest ConditionTest MethodTest Result
Tensile modulusISO527-2/1A/18500 MPa
Tensile stressBreakISO527-2/1A/5115 MPa
Tensile strainBreakISO527-2/1A/52.0 %
Flexural modulusISO1788000 MPa
Bending stressISO178180 MPa
Impact resistanceTest ConditionTest MethodTest Result
Charpy Notched Impact StrengthISO179/1eA6.0 kJ/m²
Charpy Notched Impact StrengthISO179/1eA7.0 kJ/m²
Impact strength of simply supported beam without notchISO179/1eU48 kJ/m²
Impact strength of simply supported beam without notchISO179/1eU58 kJ/m²
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.