Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTMD792 | 1.20 g/cm³ | |
ISO1183 | 1.19 g/cm³ | ||
Shrinkage rate | ASTMD955 | 0.20to0.60 % |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
Rockwell hardness | ASTMD785 | 105 |
optical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
transmissivity | ASTMD1003 | 91.0 % | |
ASTMD1003 | 89.0 % | ||
Haze ratio | ASTMD1003 | 0.30 % |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
FlameRating | UL94 | HB |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Dart impact equipped with measuring instruments | ASTMD3763 | 45.0 J | |
Multi axis Instrumented Impact Energy | ISO6603-2 | 55.0 J | |
ISO6603-2 | 71.0 J | ||
Impact strength of cantilever beam gap | ASTMD256 | 60 J/m | |
ASTMD256 | 370 J/m | ||
ISO180 | 6.3 kJ/m² | ||
ISO180 | 30 kJ/m² | ||
ASTMD4812 | NoBreak | ||
Dart impact equipped with measuring instruments | ASTMD3763 | 48.0 J | |
Impact strength of cantilever beam gap | ASTMD4812 | NoBreak |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | ASTMD638 | 46.0 MPa | |
Tensile stress | ISO527-2 | 47.0 MPa | |
tensile strength | ASTMD638 | 53.0 MPa | |
Tensile stress | ISO527-2 | 49.0 MPa | |
elongation | ASTMD638 | 5.0 % | |
Tensile strain | ISO527-2 | 4.0 % | |
elongation | ASTMD638 | 310 % | |
Tensile strain | ISO527-2 | 210 % | |
Flexural modulus | ASTMD790 | 1900 MPa | |
ISO178 | 1750 MPa | ||
Bending stress | ISO178 | 64.0 MPa | |
bending strength | ASTMD790 | 67.0 MPa |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
ASTMD648 | 73.0 °C | ||
ISO75-2/B | 73.0 °C | ||
ASTMD648 | 65.0 °C | ||
ISO75-2/A | 66.0 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.