Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
density | | ASTM D1505 | 0.910 g/cm³ |
melt mass-flow rate | | ASTM D1238 | 3.0 g/10min |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | HB |
Impact resistance | Test Condition | Test Method | Test Result |
---|
Impact strength of cantilever beam gap | | ASTM D256 | 25 J/m |
Impact strength of cantilever beam gap | | ASTM D256 | 39 J/m |
Mechanical properties | Test Condition | Test Method | Test Result |
---|
tensile strength | Yield | ASTM D638 | 37.3 MPa |
tensile strength | Break | ASTM D638 | 34.3 MPa |
elongation | Break | ASTM D638 | 500 % |
Thermal performance | Test Condition | Test Method | Test Result |
---|
Hot deformation temperature (HDT) | | ASTM D648 | 110 °C |
Hot deformation temperature (HDT) | | ASTM D648 | 60.0 °C |
vicat | | ASTM D1525 | 155 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.