Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|
melt mass-flow rate | | ASTM D1238 | 1.0to12 g/10min |
melt mass-flow rate | | ASTM D1238 | 15to25 g/10min |
Shrinkage rate | | ASTM D955 | 0.90-1.5 % |
hardness | Test Condition | Test Method | Test Result |
---|
Shore hardness | | ASTM D2240 | 65 |
flammability | Test Condition | Test Method | Test Result |
---|
UL flame retardant rating | | UL 94 | HB |
Supplementary Information | Test Condition | Test Method | Test Result |
---|
MassLoss-500CycleAbrasionResistance | | ASTM D3389 | 2.0 mg |
Filling analysis | Test Condition | Test Method | Test Result |
---|
Apparent viscosity | | ASTM D3835 | 16.0 Pa·s |
elastomer | Test Condition | Test Method | Test Result |
---|
compression set | | ASTM D395 | 24 % |
tensile strength | | ASTM D412 | 3.07 Mpa |
tensile strength | | ASTM D412 | 5.10 Mpa |
tensile strength | | ASTM D412 | 15.2 Mpa |
elongation | | ASTM D412 | 640 % |
tear strength | | ASTM D624 | 52.5 kN/m |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.