PA612 CR-9-HV EMS-CHEMIE SWITZERLAND
153
Form:Granules | Grade:Injection grade
Properties:
PhotostabilityHigh impact resistance
Typical Applications:
Electronic and electrical componentsPneumatic applications
Product Description
Certificates(0)
Datasheet
Product Description
| Typical Applications: | Electronic and electrical components | Pneumatic applications |
| Properties: | Photostability | High impact resistance |
Certificates
No Data...
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Tensile modulus | ISO 527-2 | -- | Mpa | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Equilibrium,23℃,50% RHEquilibrium, 73°F, 50% RH | ISO 62 | 2 | % |
| Saturation,23℃Saturation, 73°F | ISO 62 | 9 | % | |
| Melt Volume Flow Rate (MVR) | 275℃,5 kg275℃/5.0 kg | ISO 1133 | 30 | cm3/10min |
| density | ISO 1183 | 1.1 | g/cm³ | |
| film | Test Condition | Test Method | Test Result | Test Unit |
| Water vapor permeability | 23℃,85% RH23℃,85% RH | DIS 15106-1/-2 | 15 | g/m²/24 hr |
| Tear resistance of pants type | TDTD | ISO 6383-1 | 65 | N/mm |
| MDMD | ISO 6383-1 | 65 | N/mm | |
| Elmendorf tear strength | TDTD | ISO 6383-2 | 20 | N |
| MDMD | ISO 6383-2 | 20 | N | |
| Tensile strain | TD,BreakTD : Break | ISO 527-3 | 900 | % |
| MD,BreakMD : Break | ISO 527-3 | 800 | % | |
| TD,YieldTD : Yield | ISO 527-3 | 10 | % | |
| MD,YieldMD : Yield | ISO 527-3 | 10 | % | |
| tensile strength | TD,BreakTD : Break | ISO 527-3 | 75 | Mpa |
| MD,BreakMD : Break | ISO 527-3 | 80 | Mpa | |
| TD,YieldTD : Yield | ISO 527-3 | 30 | Mpa | |
| MD,YieldMD : Yield | ISO 527-3 | 30 | Mpa | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| ISO TypeISO Type | ISO 1874 | PA 6/12, FT, 22-020 | ||
| Yellow flex test Yellow flex test | Internal Method | 800 | holes/m² |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.