Epoxy 44N Arlon-MED
Product Description
Certificates(0)
Datasheet
Product Description
Certificates
No Data...
Technical Data Sheet
| flammability | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| UL flame retardant rating | UL 94 | V-0 | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile modulus | Internal Method | 19300 | MPa | |
| Poisson's ratio | ASTM D3039 | 0.15 | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Glass transition temperature | Internal Method | 175 | °C | |
| Linear coefficient of thermal expansion | MD:--6 | Internal Method | 1.4E-5到1.6E-5 | cm/cm/°C |
| MD:<175°C7 | Internal Method | 5.5E-05 | cm/cm/°C | |
| MD:>175°C7 | Internal Method | 2E-04 | cm/cm/°C | |
| thermal conductivity | 100°C | ASTME1461 | 0.30 | W/m/K |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792A | 1.85 | g/cm³ | |
| Water absorption rate | 24hr | Internal Method | 0.10 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Arc resistance | Internal Method | 65.0 | sec | |
| Surface resistivity | --8 | Internal Method | 4E+10 | ohms |
| --9 | Internal Method | 2.9E+13 | ohms | |
| Volume resistivity | --8 | Internal Method | 3.3E+13 | ohms·cm |
| --9 | Internal Method | 2.6E+13 | ohms·cm | |
| Dielectric strength | Internal Method | 59 | kV/mm | |
| Dielectric constant | 1MHz | Internal Method | 4.40 | |
| Dissipation factor | 1MHz | Internal Method | 0.025 | |
| film | Test Condition | Test Method | Test Result | Test Unit |
| Peel strength | --3 | Internal Method | 1.4 | kN/m |
| --4 | Internal Method | 1.4 | kN/m | |
| --5 | Internal Method | 1.4 | kN/m | |
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| expansion rate | 50to260°C | Internal Method | 2.4 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.